Package net.wimpi.modbus.io

Source Code of net.wimpi.modbus.io.ModbusASCIITransport

//License
/***
* Java Modbus Library (jamod)
* Copyright (c) 2002-2004, jamod development team
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are
* met:
*
* Redistributions of source code must retain the above copyright notice,
* this list of conditions and the following disclaimer.
*
* Redistributions in binary form must reproduce the above copyright notice,
* this list of conditions and the following disclaimer in the documentation
* and/or other materials provided with the distribution.
*
* Neither the name of the author nor the names of its contributors
* may be used to endorse or promote products derived from this software
* without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER AND CONTRIBUTORS ``AS
* IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
* THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
* PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
***/
package net.wimpi.modbus.io;

import net.wimpi.modbus.Modbus;
import net.wimpi.modbus.ModbusCoupler;
import net.wimpi.modbus.ModbusIOException;
import net.wimpi.modbus.msg.ModbusMessage;
import net.wimpi.modbus.msg.ModbusRequest;
import net.wimpi.modbus.msg.ModbusResponse;
import net.wimpi.modbus.util.ModbusUtil;

import java.io.DataInputStream;
import java.io.IOException;
import java.io.InputStream;
import java.io.OutputStream;

import util.Configuration;

/**
* Class that implements the Modbus/ASCII transport
* flavor.
*
* @author Dieter Wimberger
* @author John Charlton
* @version 1.2rc1 (09/11/2004)
*/
public class ModbusASCIITransport
  extends ModbusSerialTransport {

  private DataInputStream m_InputStream;     //used to read from
  private ASCIIOutputStream m_OutputStream;   //used to write to

  private byte[] m_InBuffer;
  private BytesInputStream m_ByteIn;         //to read message from
  private BytesOutputStream m_ByteInOut;     //to buffer message to
  private BytesOutputStream m_ByteOut;      //write frames

  /**
   * Constructs a new <tt>MobusASCIITransport</tt> instance.
   */
  public ModbusASCIITransport() {
  }//constructor
 
  public void close() throws IOException {
    m_InputStream.close();
    m_OutputStream.close();
  }//close

  public void writeMessage(ModbusMessage msg)
      throws ModbusIOException {

    try {
      synchronized (m_ByteOut) {
        //write message to byte out
        msg.setHeadless();
        msg.writeTo(m_ByteOut);
        byte[] buf = m_ByteOut.getBuffer();
        int len = m_ByteOut.size();

        //write message
        m_OutputStream.write(FRAME_START);               //FRAMESTART
        m_OutputStream.write(buf, 0, len);                 //PDU
        System.out.println("Writing: " + ModbusUtil.toHex(buf, 0, len));
        m_OutputStream.write(calculateLRC(buf, 0, len)); //LRC
        //m_OutputStream.write(248); //LRC
        m_OutputStream.write(FRAME_END);                 //FRAMEEND
        m_OutputStream.flush();
        m_ByteOut.reset();
        // clears out the echoed message
        // for RS485
        if (m_Echo) {
          // read back the echoed message
         // readEcho(len + 3);
        }
      }
    } catch (Exception ex) {
      throw new ModbusIOException("I/O failed to write");
    }
  }//writeMessage

  public ModbusRequest readRequest()
      throws ModbusIOException {

    boolean done = false;
    ModbusRequest request = null;

    int in = -1;

    try {
      do {
        //1. Skip to FRAME_START
        while ((in = m_InputStream.read()) != FRAME_START) ;
        //2. Read to FRAME_END
        synchronized (m_InBuffer) {
          m_ByteInOut.reset();
          while ((in = m_InputStream.read()) != FRAME_END) {
            if (in == -1) {
              throw new IOException("I/O exception - Serial port timeout.");
            }
            m_ByteInOut.writeByte(in);
          }
          // check LRC
          if(Configuration.CALCULATE_CHECKSUM) {
            if (m_InBuffer[m_ByteInOut.size()-1] !=
                calculateLRC(m_InBuffer, 0, m_ByteInOut.size(), 1)) {
              continue;
            }
          }
          m_ByteIn.reset(m_InBuffer, m_ByteInOut.size());
          in = m_ByteIn.readUnsignedByte();
          //check message with this slave unit identifier
          if (in != ModbusCoupler.getReference().getUnitID()) {
            continue;
          }
          in = m_ByteIn.readUnsignedByte();
          //create request
          request = ModbusRequest.createModbusRequest(in);
          request.setHeadless();
          //read message
          m_ByteIn.reset(m_InBuffer, m_ByteInOut.size());
          request.readFrom(m_ByteIn);
        }
        done = true;
      } while (!done);
      return request;
    } catch (Exception ex) {
      if(Modbus.debug) System.out.println(ex.getMessage());
      throw new ModbusIOException("I/O exception - failed to read.");
    }

  }//readRequest

  public ModbusResponse readResponse()
      throws ModbusIOException {

    boolean done = false;
    ModbusResponse response = null;
    int in = -1;

    try {
      do {
        //1. Skip to FRAME_START
        while ((in = m_InputStream.read()) != FRAME_START) {
          if (in == -1) {
            throw new IOException("I/O exception - Serial port timeout.");
          }
        }
        //2. Read to FRAME_END
        synchronized (m_InBuffer) {
          m_ByteInOut.reset();
          while ((in = m_InputStream.read()) != FRAME_END) {
            if (in == -1) {
              throw new IOException("I/O exception - Serial port timeout.");
            }
            m_ByteInOut.writeByte(in);
          }
          int len = m_ByteInOut.size();
          if (Modbus.debug)
            System.out.println("Received: " +
                               ModbusUtil.toHex(m_InBuffer, 0, len));
          //check LRC
          if(Configuration.CALCULATE_CHECKSUM) {
            if (m_InBuffer[len-1] != calculateLRC(m_InBuffer, 0, len, 1)) {
              continue;
            }
          }

          m_ByteIn.reset(m_InBuffer, m_ByteInOut.size());
          in = m_ByteIn.readUnsignedByte();
          // JDC: To check slave unit identifier in a response we need to know
          // the slave id in the request.  This is not tracked since slaves
          // only respond when a master request is made and there is only one
          // master.  We are the only master, so we can assume that this
          // response message is from the slave responding to the last request.
//           if (in != ModbusCoupler.getReference().getUnitID()) {
//             continue;
//           }
          in = m_ByteIn.readUnsignedByte();
          //create request
          response = ModbusResponse.createModbusResponse(in);
          response.setHeadless();
          //read message
          m_ByteIn.reset(m_InBuffer, m_ByteInOut.size());
          response.readFrom(m_ByteIn);
        }
        done = true;
      } while (!done);
      return response;
    } catch (Exception ex) {
      if(Modbus.debug) System.out.println(ex.getMessage());
      throw new ModbusIOException("I/O exception - failed to read.");
    }
  }//readResponse

  /**
   * Prepares the input and output streams of this
   * <tt>ModbusASCIITransport</tt> instance.
   * The raw input stream will be wrapped into a
   * filtered <tt>DataInputStream</tt>.
   *
   * @param in the input stream to be used for reading.
   * @param out the output stream to be used for writing.
   * @throws IOException if an I\O related error occurs.
   */
  public void prepareStreams(InputStream in, OutputStream out) throws IOException {
    m_InputStream = new DataInputStream(new ASCIIInputStream(in));
    m_OutputStream = new ASCIIOutputStream(out);
    m_ByteOut = new BytesOutputStream(Modbus.MAX_MESSAGE_LENGTH);
    m_InBuffer = new byte[Modbus.MAX_MESSAGE_LENGTH];
    m_ByteIn = new BytesInputStream(m_InBuffer);
    m_ByteInOut = new BytesOutputStream(m_InBuffer);
  }//prepareStreams

  private final static int calculateLRC(byte[] data, int off, int len) {

    int lrc = 0;
    for (int i = off; i < len; i++) {
      lrc += data[i];
    }
   
    lrc = 0xff - lrc + 1;
   
    return ((bytelrc );
   
  }//calculateLRC

  private final byte calculateLRC(byte[] data, int off, int length, int tailskip) {
   
    int lrc = 0;
    for (int i = off; i < length - tailskip; i++) {
      lrc += data[i];
    }
    lrc = 0xff - lrc + 1;

    return (byte) lrc;
   
  }//calculateLRC

  /**
   * Defines a virtual number for the FRAME START token (COLON).
   */
  public static final int FRAME_START = 1000;

  /**
   * Defines a virtual number for the FRAME_END token (CR LF).
   */
  public static final int FRAME_END = 2000;

}//class ModbusASCIITransport